Endress Hauser E+H 1-1/2" DN40 Proline Promass E 100 Coriolis Flow Meter

Brand Name : E+H

Model Number : 8I1B

Place of Origin : China

MOQ : 1 pc

Price : USD 600

Payment Terms : T/T

Supply Ability : 100 pc

Delivery Time : 7-14 days

Supply Voltage : 10-30 VDC

Measuring Principle : Absolute and gauge pressure

Process Connection : 1/2" NPT

Mounting Type : Threaded

Electrical Connection : M12x1

Reference Accuracy : Standard: 0.05% Platinum: up to 0.025%

Output Signal : 4-20 mA

Mounting Method : DIN rail or wall mount

Protocol : HART/RS485

Temperature Range : -40 to 185°F

Range : 0-10,000 psi

Wetted Parts Material : Stainless Steel

Material : Stainless steel

Communication Protocol : HART

Operating Temperature : -20 to 85 degrees Celsius

Contact Now

What is the Promass I 100

The Promass I 100 is a high-performance Coriolis mass flowmeter designed for industrial applications, offering measurements of mass flow, density, and temperature, with optional viscosity measurement.

It is part of the Endress+Hauser “Promass I” line, featuring a straight single-tube sensor design and very compact transmitter housing.

Measuring principle

  • The fundamental principle is Coriolis force measurement: the flow tube is vibrated and the fluid flowing through causes a phase shift in oscillations between inlet & outlet positions. This phase shift is proportional to mass flow.
  • The tube is excited at its resonance; changes in oscillation frequency due to changes in mass (tube + fluid) are used to compute density.
  • Temperature of the measuring tube is also measured, both for fluid temperature and to compensate temperature effects.

Key Technical Features & Specifications

Here are some of its important characteristics:

Feature

Details

Flow variables measured

Mass flow, density, temperature; optional viscosity.

Sensor design

Straight single-tube design; “easy cleanable”.

Tube material / wetted parts

Titanium for measuring tube; other parts in stainless steel or coating depending on version.

Size range (nominal diameter)

DN 8 to DN 80 (≈ 3/8″ to 3″).

Accuracy

• Liquids: about ±0.1 % for mass & volume flow; <-- density accuracy in liquid ~ ±0.0005 g/cm³.
• Gases: larger error, e.g. approx ±0.5 % mass flow.

Temperature / Pressure ranges

Medium temperature: from 50 °C up to approx +150 °C.
Process pressure: up to PN100 (or equivalent), specifics depending on DN, material etc.

Environmental / Protection

High ingress protection (IP69K in many versions). Robust transmitter housing.

Installation

“Full-bore” design to minimize pressure drop. As its straight tube, less demanding for inlet/outlet runs compared to bent-tube designs.

Outputs / Communication

Multiple typical industrial outputs: analog (4-20 mA with HART), digital protocols (Modbus RS-485, PROFIBUS, PROFINET, etc.), pulse/frequency/switch outputs.

Additional features

Integrated web server for local configuration, diagnostics. “Heartbeat Technology” for verification and monitoring.

Advantages

  • High accuracy and stability: Since the measurement is mass‐based and not strongly influenced by fluid viscosity, density, or flow profile, it gives very reliable readings.
  • Multi-variable measurement: Flow, density, temperature (and viscosity optionally) reduce need for multiple sensors.
  • Compact & robust: Small footprint transmitter, full-bore, straight tube helps in installations where space is limited and/or cleaning is needed.
  • Low pressure loss: Full bore and straight single tube help minimizing pressure drop. Good for sensitive fluids.
  • Good for hygiene and cleaning: Because of the easy-clean straight tube. Also options exist for hygienic/stainless housing.

Limitations / Considerations

  • Cost tends to be relatively high vs simpler flowmeters. More sophisticated construction, more electronics.
  • For very low flow or very small diameters, sensitivity and signal-to-noise becomes more challenging need to check minimum flow (cut-off) for your application.
  • The wetted materials (Titanium, stainless) have to be compatible with the fluid (chemically, abrasive, etc.). If the fluid is aggressive or contains solids, consider wear or corrosion.
  • Temperature and pressure limits: depending on the exact model; ensure your process operating envelope fits within them.
  • Maintenance might require more care (cleaning, calibration) due to the precision of the instrument.

Typical Applications

The Promass I 100 is suitable for many industrial sectors, especially where accurate mass flow + density + temperature are needed, such as:

  • Chemical process lines
  • Food & beverage where hygiene / cleaning is required
  • Pharmaceuticals
  • Oil & gas (for certain liquids/gases)
  • Skid / module builders (because of compact size)
  • Any application where pressure drop must be minimized or full-bore is preferable.


Product Tags:

DN40 Coriolis flow meter

      

Proline Promass E 100 flow meter

      

1-1/2 inch digital flow meter

      
China Endress Hauser E+H 1-1/2&quot; DN40 Proline Promass E 100 Coriolis Flow Meter wholesale

Endress Hauser E+H 1-1/2" DN40 Proline Promass E 100 Coriolis Flow Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Xiyi Central Control Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)